Bando 3630V479 Power Max Variable Speed Duraflex GL Fractional HorsepowerBando 3630V479 Power Max Variable Speed Belts extreme crosswise rigidity As Power Max belts are wide in proportion to their thickness, they must have extreme crosswise rigidity to keep them from dishing in. This dishing would cause the tensile cords to become misaligned, leading to uneven speed control and excessive wear on the cords, causing premature failure. Power Max belts provide lengthwise flexibility to bend around small sheave diameters
Type Piece Applied product CFW300 Description Communication module Complement CFW300-CPDP Application Variable speed drive Certification UL
6 POLES 2 NUMBER SPEEDS 1 RPM 3560 RPM 2 3561 RPM 3 3550 RPM 4 2955 RPM 5 2955 HERTZ 60 HERTZ 2 50 VOLTS PRIMARY 230/460 VOLTS 460 VOLTS 2 230 VOLTS 3 208 VOLTS 4 400 VOLTS 5 200 FRME 284 SHAFT CODE TS MOUNTING HORZ-FOOTED ASSEMBLY POSITION F1 MOTOR TYPE CTE OPPOSITE END BEARING 6210-2Z-J/C3 SHAFT END BEARING 6310-2Z-J/C3 AMBIENT 40 ROTATION DUAL SERVICE FACTOR 1
Bando - RPF4415 Molded notch design gives extra flexibility to reduce heat build-up and provide long belt life
Series EDP11 Panel type VFD Horsepower (HP) 30 HP Enclosure type Wall mount Thermal Managment None General enclosure options None Main voltage 460 V Control Voltage 120 V Frequency 60 Hz SCCR rating 5 kAIC Disconnect switch type Circuit Breaker rotary handle disconnect Bypass type None Control power transformer 100 VA - Open Reactor/Filter None Communication None Control options Start Pushbutton
Frame 444/5T Output 100 HP (75 kW) Number of Poles 4 Frequency 50 Hz Rated speed 1480 rpm Slip 1
3 a Heater Indicator No Heater Insulation Class F Inverter Code Inverter Duty IP Rating NONE KVA Code J Lifting Lugs Standard Lifting Lugs Locked Bearing Indicator Locked Bearing Max Speed 2700 rpm Motor Lead Termination Flying Leads Motor Type 0642M Mounting Arrangement F1 Number of Poles 4 Overall Length 18
Bando - 1610-14M-170 Synchro-Link® HT (High Torque Synchronous) belts' curvilinear tooth design improves stress distribution to provide high horsepower ratings over a wide speed range and high torque transmission at low speeds
0x(Code J) No load current 89
78 % Rated voltage 200 V Rated current 4
2x(Code K) No load current 170 A Rated torque 1060 ft
Rated current 7 A Reference CWC0 Main contact 4 NO Control voltage 180-208V 50Hz/208-240V 60Hz Terminal type Screw Attributes
7 a Front Face Code Standard Front Shaft Indicator None Heater Indicator No Heater Insulation Class F Inverter Code Not Inverter KVA Code N Lifting Lugs No Lifting Lugs Locked Bearing Indicator No Locked Bearing Motor Lead Exit Ko Box Motor Lead Termination Flying Leads Motor Lead Quantity/Wire Size 9 @ 18 AWG Motor Type 3416M Mounting Arrangement F1 Number of Poles 6 Overall Length 10